TZT N1201SA+ 35MHz-2.7GHz UV RF Antenna Analyzer SWR Meter Tester PS100/PS200 - PS100
-
There are Four Interfaces: Single Point Measurement, Scan, System Information, Calibration and Calibration
-
By default, it will enter into the single-point measurement interface
-
Aluminum alloy housing extends service life
-
The attached video shows how to properly turn on the device. The keys on the panel are 1234 from left to right, and you need to press 2 and 4 at the same time
Specifications:
-
Model: PS100/PS200
-
PS100: 137.5MHz~2.7GHz
-
PS200: 35MHz~2.7GHz
-
Frequency: 137.5MHz~2.7GHz/35MHz~2.7GHz
-
Step frequency: 1kHz
-
Display: 2.4-inch TFT, resolution 320*240 (QVGA)
- Battery compacity: 2000mAh
-
Power consumption <1.5W
-
Charging current: 400mA
-
Charging port: USB
-
Auto Power Off: 5-60 minutes
-
Measurement Parameters: Impedance, Reactance, SWR and S11
-
Resolution: 4 digit readings
-
Frequency Accuracy: <±10ppm
-
Connector: SMA-K
-
Impedance measurement range:
-
1Ω~1000Ω @frequency <1300MHz;
-
1Ω~300Ω @frequency >1300MHz (absolute impedance value)
-
Standing wave measurement range:
-
1~65 @frequency < 1300MHz;
-
1~10 @frequency >1300MHz
-
S11 (dB) measurement range: 0dB to -50dB
-
Error (single point measurement):
-
For impedance: < absolute value of impedance x 5%±0.1Ω (Z<200Ω, <1.5GHz)
-
For standing wave: < effective reading x 10%±0.1
-
For S11: 0.1dB/5° (0dB to -10dB)
-
For (dB/°): 1dB/10° (-10dB to -20dB); 5dB/20° (-20dB to -40dB)
-
Directivity: < 35dB (140MHz to 2GHz after calibration); < 30dB (2GHz to 2.7GHz)
-
Scan Points: 280
-
Output level: -18dBm
-
Operating temperature: 0°C to 40°C
-
Atmospheric pressure: 860hPa~1060hPa
Startup and Shutdown:
-
Hold down the CTRL key to turn it off by pressing the power button.
-
In the power-on state, long-press the switch button (more than 2S), and the instrument will shut down after releasing it.
-
In the power-on state, long-press the switch button (more than 2S), and the instrument will shut down after releasing it.
Suggestions to Use:
-
1. To ensure the accuracy of measurement and calibration, please warm up the instrument for at least 15 minutes.
-
2. Try to use good-quality RF cables and connectors.
-
3. The calibration cable marked next may not require calibration and be used directly.
-
4. The process of testing the cable affects the measurement accuracy. It is recommended not to select too long a test cable as much as possible.
-
5. Before measurement and calibration, please ensure that you are not in a strong wireless signal to avoid interference due to inaccurate measurement.
-
6. If you do not understand the impedance measurement itself, you can refer to the instructions and tutorials of the vector network analyzer. The instrument is equivalent to a one-port vector network analysis.
Note: Automatically changed to User Calibration for user convenience. At the same time, in order to ensure the integrity of the calibration, the automatic shutdown function is disabled.